INSTALLATION
CAUTION / NOTICE / HINT
NOTICE:
Replace the blind spot monitor sensor if it has been dropped or subjected to a severe impact.
PROCEDURE
1. INSTALL BLIND SPOT MONITOR SENSOR LH
(a) Install the blind spot monitor sensor LH with the 3 nuts.
Torque:
9.0 N·m {92 kgf·cm, 80 in·lbf}
(b) Connect the connector.
2. INSTALL BLIND SPOT MONITOR SENSOR RH
HINT:
Use the same procedure as for the LH side.
3. PERFORM BLIND SPOT MONITOR BEAM AXIS INSPECTION
(See page
)
4. PERFORM DIAGNOSTIC SYSTEM CHECK
(See page )
5. INSTALL REAR BUMPER EXTENSION LH (w/ Towing Package)
(See page )
6. INSTALL REAR BUMPER EXTENSION LH (w/o Towing Package)
(See page )
7. INSTALL REAR BUMPER EXTENSION RH (w/ Towing Package)
HINT:
Use the same procedure as for the LH side.
8. INSTALL REAR BUMPER EXTENSION RH (w/o Towing Package)
HINT:
Use the same procedure as for the LH side.
9. INSTALL REAR BUMPER PAD SUB-ASSEMBLY (w/ Towing Package)
(See page )
10. INSTALL REAR BUMPER PAD SUB-ASSEMBLY (w/o Towing Package)
(See page )
11. INSTALL CONNECTOR COVER (w/ Towing Package)
(See page )
12. INSTALL REAR BUMPER HOLE COVER (w/o Towing Package)
(See page )
13. INSTALL REAR BUMPER ASSEMBLY (w/ Towing Package)
HINT:
(See page )
14. INSTALL REAR BUMPER ASSEMBLY (w/o Towing Package)
HINT:
(See page )
Power Source Mode does not Change to ON (IG)
DESCRIPTION
If the engine switch is pressed with the electrical key transmitter sub-assembly
in the cabin, the certification ECU (smart key ECU assembly) receives a signal and
changes the power source mode.
HINT:
When the cable is disconnected and reconnected to the negative (-) battery termi ...
Automatic High Beam System does not Operate or Operation Indicator does not
Illuminate
DESCRIPTION
The main body ECU (multiplex network body ECU) controls the automatic high beam
system based on signals received from the forward recognition camera.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
NOTICE:
When replacing the combination meter assembly, always replace it with
...
Entire Combination Meter does not Operate
DESCRIPTION
This circuit is the power source circuit for the meter. This circuit provides
two types of power sources, one is a constant power source mainly used as a backup
power source, and the other is an IG power source mainly used for signal transmission.
The constant power source is main ...