DESCRIPTION
This symptom may occur for any of the windows.
The jam protection function operates within a specified range during the manual up or auto up operation.
CAUTION / NOTICE / HINT
NOTICE:
PROCEDURE
1. |
PERFORM INITIALIZATION (APPLICABLE LOCATION) |
(a) Initialize the power window regulator motor assembly (applicable location)
(See page ).
|
2. |
CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP/DOWN FUNCTION) |
(a) Check if the power window auto up/down function operates normally (See page
).
OK:
Auto up/down function is normal.
NG | ![]() |
GO TO OTHER PROBLEM (Proceed to Problem Symptoms Table) |
|
3. |
CHECK JAM PROTECTION FUNCTION OPERATING RANGE |
(a) Check if the jam protection function operates normally for the applicable power window.
HINT:
The jam protection function will not operate within 4 mm (0.157 in.) of the fully closed position.
OK:
Jam protection function operates normally.
Result
Result |
Proceed to |
---|---|
OK |
A |
NG (Driver side power window) |
B |
NG (Front passenger side power window) |
C |
A | ![]() |
END (PROBLEM DUE TO INITIALIZATION FAILURE) |
B | ![]() |
REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH |
C | ![]() |
REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH |
Magnetic Clutch Relay
Inspection
INSPECTION
PROCEDURE
1. INSPECT MAGNET-CLUTCH RELAY
(a) Check the resistance.
(1) Using an ohmmeter, measure the resistance between the terminals.
Standard:
Tester Connection
Specified Condition
3 - 5
...
Hydraulic Test
HYDRAULIC TEST
1. PERFORM HYDRAULIC TEST
(a) Measure the line pressure.
CAUTION:
The line pressure test should always be performed with at least 2 people. One
person should observe the condition of the wheels and wheel chocks while the other
is performing the test.
NOTICE:
Perform ...
Data List / Active Test
DATA LIST / ACTIVE TEST
1. DATA LIST
NOTICE:
In the table below, the values listed under "Normal Condition" are reference
values. Do not depend solely on these reference values when deciding whether a part
is faulty or not.
HINT:
Using the Techstream to read the Data List allows t ...