PROBLEM SYMPTOMS TABLE
HINT:
Symptom |
Suspected Area |
See page |
---|---|---|
No Cool Air Comes Out: |
Volume of refrigerant |
- |
Air conditioner pressure sensor circuit |
|
|
Air conditioning compressor magnetic clutch circuit |
|
|
Compressor lock sensor circuit |
|
|
Evaporator temperature sensor circuit |
|
|
Air conditioner amplifier assembly |
|
|
Wire harness or connector |
- |
|
No Cool Air Comes Out: |
Blower resistor |
|
Blower motor with fan sub-assembly |
|
|
Air conditioning control assembly |
|
|
Wire harness or connector |
- |
|
No Cool Air Comes Out: |
No. 2 air conditioning radiator damper servo sub-assembly (for air mix) |
|
Air conditioning control assembly |
|
|
Wire harness or connector |
- |
|
No Cool Air Comes Out: |
Volume of refrigerant |
- |
Blower motor performance check |
- |
|
Air mix damper servo full travel check |
- |
|
Recirculation damper servo operation check |
- |
|
No Engine Idle-up when A/C Switch ON |
Air conditioner amplifier assembly |
|
SFI system (2TR-FE) |
|
|
SFI system (2GR-FKS) |
|
|
Wire harness or connector |
- |
|
No Warm Air Comes Out: |
Blower resistor |
|
Blower motor with fan sub-assembly |
|
|
Air conditioning control assembly |
|
|
Wire harness or connector |
- |
|
No Warm Air Comes Out: |
No. 2 air conditioning radiator damper servo sub-assembly (for air mix) |
|
PTC heater circuit*1 |
|
|
Air conditioning control assembly |
|
|
Wire harness or connector |
- |
|
No Warm Air Comes Out: |
Volume of engine coolant |
- |
Air conditioning control assembly |
|
|
Blower motor performance check |
- |
|
Air mix damper servo full travel check |
- |
|
Recirculation damper servo operation check |
- |
|
Heater radiator |
- |
|
Air Not Coming From Desired Outlets: |
Blower resistor |
|
Blower motor with fan sub-assembly |
|
|
Air conditioning control assembly |
|
|
Wire harness or connector |
- |
|
Air Not Coming From Desired Outlets: |
No. 2 air conditioning radiator damper servo sub-assembly (for air mix) |
|
Air conditioning control assembly |
|
|
Wire harness or connector |
- |
|
Windshield Fogging: |
Volume of refrigerant |
- |
Air conditioner pressure sensor circuit |
|
|
Air conditioning compressor magnetic clutch circuit |
|
|
Compressor lock sensor circuit |
|
|
Evaporator temperature sensor circuit |
|
|
Air conditioner amplifier assembly |
|
|
Wire harness or connector |
- |
|
Windshield Fogging: |
Blower resistor |
|
Blower motor with fan sub-assembly |
|
|
Air conditioning control assembly |
|
|
Wire harness or connector |
- |
|
Windshield Fogging: |
No. 2 air conditioning radiator damper servo sub-assembly (for air mix) |
|
Air conditioning control assembly |
|
|
Wire harness or connector |
- |
|
Windshield Fogging: |
Volume of refrigerant |
- |
Blower motor performance check |
- |
|
Air mix damper servo full travel check |
- |
|
Recirculation damper servo operation check |
- |
|
Defrosting Insufficient: |
Blower motor with fan sub-assembly |
|
Mode doors: Check cooling, heating & door operation |
- |
|
Mode control servo motor: Hot air not coming, Go to no hot air comes out |
- |
|
Mode control servo motor: Cold air not coming, Go to no cold air comes out |
- |
|
Noise: |
Blower motor: Inspect blower motor for debris/cracks |
- |
Fresh air intake area: Inspect fresh air intake area for debris |
- |
|
Noise: |
Cooler compressor: Cooler compressor incorrectly fitted |
- |
Air conditioning compressor magnetic clutch circuit |
|
|
Refrigerant charge amount |
- |
|
Compressor mounting bracket: Compressor mounting bracket incorrectly fitted |
- |
|
A/C lines secure & not grounded |
- |
|
Odor (Cycle through blower speed, mode, temperature to define odor type when engine is running and A/C switch is ON. (Musty smell, coolant oil smell)) |
Wet carpet: Inspect water, engine coolant or oil leaks |
- |
A/C drain tube: Inspect water, engine coolant or oil leaks |
- |
|
Fresh air intake area: Inspect water, engine coolant or oil leaks |
- |
|
Heater hose: Inspect water, engine coolant or oil leaks |
- |
|
Evaporator: Inspect water, engine coolant or oil leaks |
- |
|
Evapo case: Inspect water, engine coolant or oil leaks |
- |
|
Air Not Coming from Desired Outlets (Cycle the mode lever and check airflow for outlets when engine is running, A/C switch is ON.) |
Blower motor with fan sub-assembly |
|
No. 1 air conditioning radiator damper servo sub-assembly (for mode switching) |
|
|
Mode doors: Check cooling, heating & door operation |
- |
|
Wire harness or connector |
- |
|
Air conditioning control assembly |
|
|
The temperature control dial is rotated to the MAX A/C position, but the MAX A/C mode is not activated. |
No. 2 air conditioning radiator damper servo sub-assembly (for air mix) |
|
Air conditioning control assembly |
|
|
Air conditioning amplifier assembly |
|
|
Wire harness or connector |
- |
|
Quick heater assembly does not operate*1 |
PTC heater circuit |
|
Air conditioning amplifier assembly |
|
|
ECM (for 2TR-FE) |
|
|
ECM (for 2GR-FKS) |
|
Front Radar Sensor (C1A10)
DESCRIPTION
C1A10 is output when there is an internal malfunction in the millimeter wave
radar sensor assembly.
DTC No.
Detection Item
DTC Detection Condition
Trouble Area
MIL
C1A10
Front Radar Sensor
W ...
Dtc Check / Clear
DTC CHECK / CLEAR
HINT:
When using the Techstream with the engine switch off to troubleshoot:
Connect the Techstream to the DLC3 and turn a courtesy light switch on and
off at 1.5 second intervals until communication between the Techstream and
vehicle begins.
Refer to the T ...
Open in Bus 5 Main Bus Line
DESCRIPTION
There may be an open circuit in one of the CAN main bus lines when the resistance
between terminals 15 (CA5H) and 16 (CA5L) of the central gateway ECU (network gateway
ECU) is 70 Ω or higher.
Detection Item
Trouble Area
Resistance between ter ...