CUSTOMIZE PARAMETERS
1. CUSTOMIZE METER / GAUGE SYSTEM
(a) Customizing with the Techstream
(1) Connect the Techstream to the DLC3.
(2) Turn the ignition switch to ON.
(3) Turn the Techstream on.
(4) Enter the following menus: Customize Setting / Warning or Display.
(5) Select the setting by referring to the table below.
NOTICE:
Record the current settings before customizing.
Warning
Display |
Default |
Content |
Setting |
Relevant ECU |
---|---|---|---|---|
Key Remind Volume |
Large |
Function to change the volume of the key reminder buzzer. |
Large,Medium,Small |
Combination meter assembly |
Key Remind Sound |
Normal |
Function to change the frequency of the key reminder buzzer. |
Normal,Slow,Fast |
Combination meter assembly |
Display |
Default |
Content |
Setting |
Relevant ECU |
---|---|---|---|---|
ODO Display Time After IG OFF Setting |
30s |
Function to change the ODO Display Time After IG OFF Setting. |
30s,60s,600s,OFF |
Combination meter assembly |
Data List / Active Test
DATA LIST / ACTIVE TEST
1. READ DATA LIST
HINT:
Using the Techstream to read the Data List allows the values or states of switches,
sensors, actuators and other items to be read without removing any parts. This non-intrusive
inspection can be very useful because intermittent conditions or sig ...
Disassembly
DISASSEMBLY
PROCEDURE
1. INSPECT CONNECTING ROD THRUST CLEARANCE
(a) Using a dial indicator, measure the thrust clearance while moving
the connecting rod back and forth.
Standard thrust clearance:
0.15 to 0.40 mm (0.00591 to 0.0157 in.)
Maximum thrust clearance:
0.50 ...
Installation
INSTALLATION
PROCEDURE
1. INSTALL TRANSMISSION FLOOR SHIFT ASSEMBLY
(a) Install the transmission floor shift assembly to the vehicle body with the
4 bolts.
Torque:
14 N·m {143 kgf·cm, 10 ft·lbf}
(b) Attach the 4 clamps to connect the wire harness to the transmission floor
shift assembl ...